A tall, white laboratory freezer with a stainless steel handle, digital temperature display at the bottom, and warning labels indicating flammable material storage and safety precautions on the front door. The American BioTech Supply logo is visible at the top. A white, upright refrigerator with its door open, showing four empty metal shelves and a plain door interior with a handle. A digital control panel is visible at the bottom front of the fridge. The interior is clean and well-lit.
A tall, white laboratory freezer with a stainless steel handle, digital temperature display at the bottom, and warning labels indicating flammable material storage and safety precautions on the front door. The American BioTech Supply logo is visible at the top.
A white, upright refrigerator with its door open, showing four empty metal shelves and a plain door interior with a handle. A digital control panel is visible at the bottom front of the fridge. The interior is clean and well-lit.

30 Cu. Ft. Standard Flammable Storage Freezer

Product Number: ABT-HC-FFS-30

This flammable storage freezer offers a secure solution for storing volatile materials in laboratory and industrial settings. This model meets NFPA and OSHA guidelines 45 and 70 for the refrigerated storage of flammable (volatile) materials in general laboratory work areas. Its temperature control is powered by microprocessor technology, protecting samples down to -25°C. A series of audible and visual alarms safeguards stored contents. Utilizing hydrocarbon refrigerants, this unit also meets EPA SNAP compliance, protecting environmental safety. With low energy consumption and high safety standards, this freezer is an efficient and dependable solution for the safe storage of flammable substances.

A minimalist leaf icon with a gradient color transition from blue at the top to green at the bottom. The leaf features a simple, stylized design with a vertical line down the center, resembling a stem, and two side veins.ul

Request a Custom Quote

Get pricing and availability for this product

Storage capacity (cu. ft) 30 Cu. Ft.
Door One (1) solid swing, right hinged; stainless steel door handle; magnetic door gasket
Shelves Four (4) fixed evaporator shelves
Mounting and Installation Leveling legs
External probe access 3/4″ probe access port on rear wall
Insulation EPA compliant high density urethane foam
Exterior materials Powder coated steel
Access control Keyed door lock
General warranty Two (2) year parts and labor warranty
Compressor warranty Five (5) year compressor parts warranty
Product Weight (lbs) 300
Shipping Weight (lbs) 330
Rated Amperage 3.3 Amps
Power Plug/Power Cord NEMA 5-15P plug, 6 ft long cord
Facility Electrical Requirement 110 – 120V AC, 15A breaker, NEMA 5-15 receptacle
Agency Listing and Certification No. 120 standard, Units meet NFPA guidelines 45 and 70 for flammable materials
Uniformity (Cabinet air) +/- 3°C
Stability (Cabinet air) +/- 3°C
Maximum temperature variation (Cabinet air) 7°C Total
Energy Consumption (kWh/day) 4.9 kWh/day
Average Heat Rejection (BTU/hr) 690 BTU/hr
Pull down time to nominal operating temp 65 min (empty)
Compressor Hermetic, variable speed
Refrigerant EPA SNAP compliant R290 propane
Condenser Static – exterior walls of cabinet with auxiliary fan
Evaporator Evaporator shelves
Defrost Manual defrost
Controller technology Microprocessor temperature controller with variable frequency compressor control
Battery Backup N/A
Display technology Digital temperature display, sample simulated digital temperature display; .1° resolution
Adjustable Temperature Range -15° C to -25° C
External alarm connection Remote alarm contacts
Alarms Audible and visual high/low-temperature alarms, door ajar alarm, remote alarm contacts
Display Probe Product simulator bottle with glass bead media
Disclaimers Defrosting of the unit will need to be performed periodically to prevent severe ice build-up. Indoor use only, +18° C to +26° C (+65° F to +78° F), <70% RH Specifications are subject to change. Equipment requires 4” of clearance around back and sides of the unit for proper ventilation – improper installation will void the warranty and will lead to temperature maintenance issues, overheating and possible failure. Performance claims are based on testing at 22°C ambient using unbuffered air temperatures in an empty freezer at steady state operation. Performance may vary with environmental conditions, product load, or door openings.

Inquire About This Product

This field is for validation purposes and should be left unchanged.
Name(Required)
Email(Required)
Which State is Your Business Located(Required)
US Based Phone Number Only (###) ###-####
Preferred Contact Method(Required)
If you have any additional questions, enter them here
By submitting a request, you agree and consent to the use of your information in accordance with our Privacy Policy
×

Email Product Datasheet

Enter your information to receive the product datasheet via email.

Quote Cart
Looking for a multi-product quote? Simply add items to your Quote Cart and send us your request. It’s quick and easy.
Browse NSF Products
🔥