user-circle-o search facebook linkedin2 twitter document-download info

ABS Auto Jr, 6000 Vials Polycarbonate Package System

Product Number: AJ-IV PS

The unique fiberglass restricted-opening neck design of the ABS Auto Jr. reduces LNconsumption rates far below other auto-filling units. Under laboratory testing providing one opening per day, the ABS Auto Jr. operated and maintained “cryogenic temperatures” for over a month on one 180-liter LN supply tank. Competitive units can consume three or four supply tanks per month. 

The Auto Jr is the economical auto-fill for every lab. Every Auto Jr comes standard with: 6ft. stainless-steel armor-plated transfer hose, 1/3 year parts and labor warranty, roller base, stainless steel inventory racks, and the Sentry LNController.

ABS Auto Jr. Polycarbonate package systems include: ABS Auto Jr. Tank, Sentry LNController, stainless steel rack inventory system, transfer hose, CryoGloves, LN measuring rod, and polycarbonate boxes (25 cell, 81 cell, or 100 cell).

  • Sentry Controller
  • UL-Listed Transformer
  • Stainless steel armor-plated transfer hose
  • (6) 10-2 Hanging Racks (10 Boxes per rack)
  • (60) 81/100 cell Polycarbonate Boxes
  • State of the art hanging rack design
  • Liquid Level Measuring Ruler
  • One pair of CryoGloves
  • Cast aluminum roller base
  • Lid with locking provision & protective boot
  • Fiberglass restricted opening neck design
  • Stainless steel vacuum tank
  • Liquid Level Measuring Ruler
  • One-year warranty on all parts and labor
  • Three-year vacuum warranty
  • Total Vial Capacity (2 ml Vial) – 6000
  • Total Box Capacity* – 60
  • Rack Capacity – 6
  • Boxes Per Rack – 10
  • Vials Per Box (2 ml) – 100
  • LNCapacity (Liters) – 165
  • Static Evaporation Rate** (Liters/Day) – 0.84
  • Static Holding Time** (Days) – 194
  • Power Requirement – 24 VAC
  • Neck Diameter (mm) – 215.9
  • Exterior Height (mm) – 990.6
  • Exterior Diameter (mm) – 683.3

*Storage Boxes are 5 1/5” x5 1/5” ‘x 2″ with a cell capacity between 16-144.
**Static Evaporation Rate and Static Holding Time are nominal. Actual rate may be affected by the nature of the contents, atmospheric conditions, container history and manufacturing tolerances.

  • Temperature Display (°C)
  • Level accuracy with 4 direct read sensors
  • Large Format LED Display
  • Alarm Ringback
  • Redundant Level Sensor System
  • Liquid Level Indicator
  • Alarm Package (Audible, Visual and Remote)
    º     Level, High and Low
    º     High Temperature
    º     Sensor Failure
  • Remote Monitoring System Available