26 Cu. Ft. Capacity Standard Certified to NSF/ANSI 456 Pharmacy Glass Door Refrigerator

Product Number: PH-ABT-NSF-S26G
EnergyStarETL_Sanitation-listed3intertek-etl-listed-us-mark-seeklogo31 (002)*ul*Green-Leaf-ABS

These standard upright refrigerators are designed in accordance with the NSF/ANSI 456 Standard for Vaccine Storage. Refrigerators protect pharmaceuticals at optimal temperatures, preventing waste and allowing for peak delivery.

These glass door refrigerators utilize microprocessor controllers and feature temperature alarms, remote alarm contacts, LED interior lighting, and probe access ports. American Biotech Supply Vaccine Storage Refrigerators utilize HFC-free refrigerant for environmental health and energy efficiency.

For more information on Vaccine Storage: Vaccine Storage
The acceptable temperature ranges for vaccine storage are 36°F to 46°F (or 2°C and 8°C) in the refrigerator and -58°F and 5°F (or -50°C and -15°C) in freezers.

*-one or more of these certifications may apply to this unit.

Description Single Glass Door Pharmacy/Vaccine Upright Refrigerator
Operational environment Indoor use only, +18°C to +26°C (+65°F to +78°F), <70% RH
Storage capacity 26 cu. ft. gross volume
Door One swing glass door, self-closing, right hinged, non-reversible, magnetic sealed gasket, keyed lock
Shelves Seven shelves (six adjustable/one fixed) with guard rail on back
Mounting 3 1/2" Swivel Casters (two locking)
Interior lighting Shielded, switched LED lighting, full coverage, balanced spectrum
Airflow management Forced Air technology, patent pending
External probe access Rear wall port (3/4") dia.
Insulation Cabinet is foamed-in-place with EPA compliant high density urethane foam
Exterior materials White powder coated steel
Access control Pyxis®, Omnicell® and AcuDose RX® compatible
General warranty Two (2) years parts and labor warranty, excluding display probe calibration
Compressor warranty Five (5) years compressor warranty
Product Weight 321 lbs.
Shipping Weight 361 lbs.
Rated Amperage 3 Amps
Power Plug/Power Cord NEMA 5-15 plug, 8 to 10 ft typical, conforms to UL471 requirements, Vaccine Storage power cord warning label
Facility Electrical Requirement 110-120V AC: 15 A (minimum)
Agency Listing and Certification Certified with the temperature performance requirements as defined in the NSF/ANSI 456 Standard for Vaccine Storage for all testing scenarios. UL, C-UL, ETL, C-ETL listed and certified to UL471 standard, hydrocarbon refrigerant safety.
Included Accessories Temperature monitor device (TMD) complies with the current CDC guidelines, with 3 years certification of calibration, “buffered” probe in the product simulated solution, min/max memory, field installable, and visual & audible temp alarm

Pharmacy refrigerator/freezer toolkit and temperature logs

Uniformity¹ (Cabinet air) +/- 0.7°C
Stability² (Cabinet air) +/- 0.5°C
Maximum temperature variation (Cabinet air) +/-0.9°C
Temperature rise after 8 sec door openings Temperature did not exceed 7.1°C at any probe for all required NSF/ANSI 456 testing protocolsᶟ
Recovery after 3 min door opening All probes recover to under 8°C within 8 min.
Energy consumption 1.68 KWh/day⁴
Average heat rejection 2.62 KWh/day (372 BTU/h)⁴
Noise pressure level (dBA) 49 or less installed
Pull down time to 4°C nominal operating temp 30 min

Controller technology Parametric, microprocessor, LED display with 0.1°C resolution
Display technology NSF/ANSI 456 Standard for Vaccine Storage compliant digital temperature display and alarm module with battery back-up, F/C switchable.
Temperature setpoint range 1°C to 10°C (Controller settings must remain unaltered to ensure thermal performance compliant with NSF/ANSI 456 Standard for Vaccine Storage requirements)
Display probe Calibrated, stainless steel
External alarm connection State switching remote alarm contacts
Alarms Visual and audible indicators
High / Low temperature, compliant with alarm requirements defined in the NSF/ANSI 456 Standard for Vaccine Storage
Simulator ballast Glass bead thermal media