user-circle-o search facebook linkedin2 twitter document-download info
Standard Series
A tall, white medical refrigerator on wheels with a glass door, three adjustable shelves, a digital temperature display at the top, and interior LED lighting. The ABS logo is on the upper left, and the door has a large handle on the left side. A tall, white laboratory refrigerator with a glass door is open, showing three adjustable wire shelves and a blue thermometer inside. The fridge has a digital display reading -40°C and is on four wheels. The brand ABS is visible on the upper left corner.
A tall, white medical refrigerator on wheels with a glass door, three adjustable shelves, a digital temperature display at the top, and interior LED lighting. The ABS logo is on the upper left, and the door has a large handle on the left side.
A tall, white laboratory refrigerator with a glass door is open, showing three adjustable wire shelves and a blue thermometer inside. The fridge has a digital display reading -40°C and is on four wheels. The brand ABS is visible on the upper left corner.

Enter your email to receive this document

This field is for validation purposes and should be left unchanged.
Name(Required)
Email(Required)
By submitting a request, you agree and consent to the use of your information in accordance with our Privacy Policy


You maybe required to confirm your email address within 2hrs to complete this request. Check your inbox.

12 Cu. Ft. Standard Glass Door Laboratory Refrigerator

Product Number: ABT-VS-LS-12
ALSO AVAILABLE IN THESE SIZES16 20 23 26 33 36 47 49 69 72 CU. FT.

These laboratory refrigerators are designed for reliable and cost-effective cold storage. This model features ultra-low energy consumption and energy efficient natural refrigerants. Using microprocessor temperature technology, this unit delivers precise temperature monitoring and control. It offers essential security features, including a keyed door lock and temperature alarms, along with remote alarm contacts. Enjoy durable powder-coated steel construction, glass door transparency, and adjustable inner shelving to optimize your workflow. All features are designed to heighten performance and efficiency in your lab.

Request a Custom Quote

Get pricing and availability for this product

Gelu

Ask Gelu about the ABT-VS-LS-12

Here are common questions and answers about this product

Gelu is on every product pageJust ask a question, anytime
What temperature range can I set on this refrigerator?

The adjustable temperature range is 2° C to 15° C. The microprocessor controller is C°/F° switchable with a resolution of 0.1° C/0.2° F.

Temp Controller tab
What are the exterior dimensions and weight?

The exterior is 25″ wide, 29″ deep, and 66″ high. Product weight is 221 lbs. and shipping weight is 254 lbs.

Details tab
How much clearance does the unit need for ventilation?

A minimum of 2” of clearance is required at the back and sides of the unit for proper ventilation.

Temp Controller tab
What electrical service does it require?

The facility requirement is 110 – 120V AC with a 15A breaker and a NEMA 5-15 receptacle. The unit has a rated amperage of 2 and comes with a NEMA 5-15 plug.

Details tab
What alarms and remote monitoring options are included?

The unit has audible and visual high/low temperature alarms, and remote alarm contacts for external alarm connection. A probe access port (3/4″) is provided on the rear wall.

Temp Controller tab
What refrigerant and defrost type does this unit use?

It uses EPA SNAP compliant R600a Isobutane, a hydrocarbon natural refrigerant, with a hermetic compressor and cycle defrost.

Refrigeration System tab
Answers come from this product's record and datasheet. Settings and procedures come from the owner's manual.

Product details for the ABT-VS-LS-12

The description, performance figures and controller details, straight from the datasheet.

Need the full datasheet? Use View / Print Product Information above.
Storage capacity
12 Cu. Ft.
Door
One (1) swing glass door, self-closing, right hinged, not reversible, magnetic door gasket
Shelves
Three (3) adjustable shelves (adjustable in ½” increments)
Mounting and Installation
Swivel casters – locking front casters
Interior lighting
LED interior lights are safety shielded and switch controlled
External probe access
Probe access port (3/4″) on rear wall
Insulation
Cabinet is foamed-in-place with EPA compliant high density urethane foam
Exterior materials
White powder coated steel
Access Control
Keyed door lock; compatible with optional digital lock (including Pyxis, Omnicell, and AcuDose RX)
General warranty
Two (2) year parts and labor warranty
Compressor  warranty
Five (5) year compressor warranty
Product Weight   (lbs.)
221
Shipping Weight (lbs.)
254
 Exterior Width       (in)
25″
 Exterior Depth      (in)
29″
 Exterior Height     (in)
66″
Rated Amperage
2
Power Plug/Power Cord
NEMA 5-15 plug
Facility Electrical Requirement
110 – 120V AC, 15A breaker, NEMA 5-15 receptacle
Agency Listing and Certification
ETL, C-ETL listed.
Compressor
Hermetic
Refrigerant
EPA SNAP compliant R600a Isobutane (Hydrocarbon natural refrigerant)
Condenser
Tube and grid, high efficiency fan forced air
Evaporator
Fin and tube, high efficiency fan forced air
Defrost
Cycle defrost
Controller  technology
Microprocessor temperature controller, C°/F° switchable, resolution is 0.1° C/0.2° F
Max temp      variation – cabinet   air (°C):
+/- 2.5° C
Energy    consumption (KWh/day):
<0.9 KWh/day
Stability – simulator ballast (°C):
+/- 0.5° C
Average heat rejection (BTU/h)
< 250 BTU/h
Display      Technology
Digital Temperature Display
Noise pressure    level (dBA)
40 dBA or less installed
Pull down time to nominal operating temp
< 30 min (empty)
Adjustable Temperature     Range
2° C to 15° C
External alarm connection
Remote alarm contacts
Display Probe
Product simulator bottle with glass bead media
Alarms
Audible and visual high/low temperature alarms, remote alarm contacts
Disclaimers
Refrigerator requires a minimum 2” of clearance at back and sides of the unit for proper ventilation
Performance     Notes
Max temperature variation based on an empty chamber at steady state using 15 bare (unweighted) thermocouple probes. Product loading, door openings, and ambient conditions will affect performance. Stability of simulator ballast based on bottle probe provided with the unit located center of empty chamber at steady state, no door openings

Inquire About This Product

This field is for validation purposes and should be left unchanged.
Name(Required)
Email(Required)
Which State is Your Business Located(Required)
US Based Phone Number Only (###) ###-####
Preferred Contact Method(Required)
If you have any additional questions, enter them here
By submitting a request, you agree and consent to the use of your information in accordance with our Privacy Policy
🔥