NSF/ANSI 456 Certified
A ADA-compliant white medical refrigerator by American BioTech Supply with a digital display, labeled Med Fridge on the left hinged solid door. It features a vertical handle and an NSF/ANSI certification sticker in the lower right corner. The fridge sits on metal legs. Laboratory refrigerator with white exterior, open door revealing three wire shelves, digital temperature display with red numerals on the top panel, and electrical outlets along the interior upper.
A ADA-compliant white medical refrigerator by American BioTech Supply with a digital display, labeled Med Fridge on the left hinged solid door. It features a vertical handle and an NSF/ANSI certification sticker in the lower right corner. The fridge sits on metal legs.
Laboratory refrigerator with white exterior, open door revealing three wire shelves, digital temperature display with red numerals on the top panel, and electrical outlets along the interior upper.

Enter your email to receive this document

This field is for validation purposes and should be left unchanged.
Name(Required)
Email(Required)
By submitting a request, you agree and consent to the use of your information in accordance with our Privacy Policy


You maybe required to confirm your email address within 2hrs to complete this request. Check your inbox.

4.6 Cu. Ft. Built-in Solid Door Vaccine Refrigerator Left Hinged ADA Certified to NSF/ANSI 456

Product Number: PH-ABT-NSF-UCBI-0404-ADA-LH
ALSO AVAILABLE IN THESE SIZES1 1 LH 2.5 5.2 CU. FT.

These premier built-in undercounter refrigerators are designed in accordance with the NSF/ANSI 456 Standard for Vaccine Storage. Refrigerators protect pharmaceuticals at optimal temperatures, preventing waste and allowing for peak delivery.

The ADA compliant, solid door refrigerators utilize microprocessor controllers and feature temperature alarms, remote alarm contacts, and probe access ports with included probes. American Biotech Supply Vaccine Storage Refrigerators utilize HFC-free refrigerant for environmental health and energy efficiency.

For more information on Vaccine Storage: Vaccine Storage
The acceptable temperature ranges for vaccine storage are 36°F to 46°F (or 2°C and 8°C) in the refrigerator and -58°F and 5°F (or -50°C and -15°C) in freezers.

*-one or more of these certifications may apply to this unit.

 

Request a Custom Quote

Get pricing and availability for this product

Gelu

Ask Gelu about the PH-ABT-NSF-UCBI-0404-ADA-LH

Here are common questions and answers about this product

Gelu is on every product pageJust ask a question, anytime
What temperature setpoint range does the controller support?

The temperature setpoint range is 1°C to 10°C. The setpoint must remain unaltered from the factory setting to remain compliant with NSF/ANSI 456 Standard for Vaccine Storage requirements.

Temp Controller tab
What are the exterior dimensions and weight?

Exterior width is 23 7/8″, exterior depth is 24 3/8″, and exterior height is 31 15/16″. Product weight is 100 lbs. and shipping weight is 140 lbs.

Description tab
What are the electrical requirements?

The unit draws 1.74 Amps and requires a facility electrical supply of 110-120V AC with a 15 A minimum circuit. It ships with a NEMA 5-15 plug and an 8 to 10 ft typical power cord that conforms to UL471 requirements.

Description tab
What shelving does it come with?

It includes three shelves (two adjustable and one fixed) with a guard rail on the back.

Description tab
What alarms and remote monitoring features are included?

The microprocessor controller provides High / Low temperature alarms compliant with the alarm requirements defined in the NSF/ANSI 456 Standard for Vaccine Storage, and offers state switching remote alarm contacts for external alarm connection.

Temp Controller tab
What warranty is provided?

It comes with a two (2) year parts and labor warranty, excluding display probe calibration, and a five (5) year compressor warranty.

Description tab
What does NSF/ANSI 456 certified mean, and who is it for?

NSF/ANSI 456 is the vaccine storage standard from NSF International, which sets performance and construction requirements for vaccine refrigerators and freezers. A certified unit like this one is tested by an independent third-party lab under protocols that go far beyond those for a standard pharmacy refrigerator: vaccine simulation devices are placed at worst-case positions inside the unit and temperatures are recorded 30 to 90 times faster than a typical data logger. It holds temperature within ±0.5°C, with forced-air circulation and dual temperature monitoring with audible and visual alarms. It is for anyone who stores vaccines or other temperature-sensitive pharmaceuticals and needs certified protection through heavy use and frequent door openings: pharmacies, clinics, physician offices, hospitals and immunization programs.

American Biotech Supply
Answers come from this product's record and datasheet. Settings and procedures come from the owner's manual.

Product details for the PH-ABT-NSF-UCBI-0404-ADA-LH

The description, performance figures and controller details, straight from the datasheet.

Need the full datasheet? Use View / Print Product Information above.
Description
Single Solid Door Pharmacy/Vaccine Undercounter Refrigerator Built-In ADA Compliant Left Hinge
Operational environment
Indoor use only, +18°C to +26°C (+65°F to +78°F), <70% RH
Storage capacity
4.6 cu. ft. gross volume
Door
One swing solid door, self-closing, left hinged, non-reversible, magnetic sealed gasket, keyed lock
Shelves
Three shelves (two adjustable/one fixed) with guard rail on back
Mounting
Low profile roller wheels and leveling legs
Interior lighting
NA
Airflow management
Forced Air technology, patent pending
External probe access
Rear wall port (1/2″) dia.
Insulation
Cabinet is foamed-in-place with EPA compliant high density urethane foam
Exterior materials
White powder coated steel
Access control
Pyxis®, Omnicell® and AcuDose RX® compatible
General warranty
Two (2) years parts and labor warranty, excluding display probe calibration
Compressor warranty
Five (5) years compressor warranty
 Exterior Width
23 7/8″
 Exterior Depth
24 3/8″
 Exterior Height
31 15/16″
Product Weight
100 lbs.
Shipping Weight
140 lbs.
Rated Amperage
1.74 Amps
Power Plug/Power Cord
NEMA 5-15 plug, 8 to 10 ft typical, conforms to UL471 requirements, Vaccine storage power cord warning label
Facility Electrical Requirement
110-120V AC: 15 A (minimum)
Agency Listing and Certification
Certified in accordance with the NSF/ANSI 456 Standard for Vaccine Storage. UL, C-UL, ETL, C-ETL listed (either single or dual agency listings) and certified to UL471 standard, hydrocarbon refrigerant safety.
Included Accessories
Pharmacy refrigerator/freezer toolkit and temperature logs

 

Uniformity¹ (Cabinet air)
+/- 0.8°C
Stability² (Cabinet air)
+/- 1.2°C
Maximum temperature variation (Cabinet air)
+/- 1.4°C
Temperature rise after 8 sec door openings
Temperature did not exceed 6.4°C at any probe for all required NSF/ANSI 456 testing protocolsᶟ
Recovery after 3 min door opening
All probes recover to under 8°C within 4.8 min.
Energy consumption
1.15 KWh/day⁴
Average heat rejection
1.57 KWh/day (224 BTU/h)⁴
Noise pressure level (dBA)
43 or less installed
Pull down time to nominal operating temp
35 min
Controller technology
Parametric, microprocessor, LED display with 0.1°C resolution
Temperature setpoint range
1°C to 10°C (Setpoint must remain unaltered from the factory setting to remain compliant with NSF/ANSI 456 Standard for Vaccine Storage requirements)
Calibration
Calibrated using a NIST traceable device, certificate included
External alarm connection
State switching remote alarm contacts
Recovery after 3 min door opening
All probes recover to under 8°C within 4.8 min.
Alarms
High / Low temperature, compliant with alarm requirements defined in the NSF/ANSI 456 Standard for Vaccine Storage
Simulator ballast
Glass bead thermal media

Inquire About This Product

This field is for validation purposes and should be left unchanged.
Name(Required)
Email(Required)
Which State is Your Business Located(Required)
US Based Phone Number Only (###) ###-####
Preferred Contact Method(Required)
If you have any additional questions, enter them here
By submitting a request, you agree and consent to the use of your information in accordance with our Privacy Policy
🔥